Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/52432
Files in This Item:
File Description SizeFormat 
ARTIGO_EmpiricalStudyRelationship.pdf2,23 MBAdobe PDFView/Open
Title: Empirical study of the relationship of architectural form details to the state of conservation of modern heritage through damage maps
Authors: Kaminski, Matheus Gregorio
Aciole, Paulo Henrique de Sá
Zanoni, Vanda Alice Garcia
metadata.dc.identifier.orcid: https://orcid.org/0009-0002-5123-3325
https://orcid.org/0009-0009-9889-608X
https://orcid.org/0000-0003-2629-4214
metadata.dc.contributor.affiliation: Universidade de Brasília, Faculdade de Arquitetura e Urbanismo
Universidade de Brasília, Faculdade de Arquitetura e Urbanismo
Universidade de Brasília, Faculdade de Arquitetura e Urbanismo
Assunto:: Conservação
Manutenção
Inspeção predial
Issue Date: 2025
Publisher: MDPI
Citation: KAMINSKI, Matheus Gregório; ACIOLE, Paulo Henrique de Sá; ZANONI, Empirical study of the relationship of architectural form details to the state of conservation of modern heritage through damage maps. Buildings, S. l., v. 15, n. 1, 142, 2025. DOI: https://doi.org/10.3390/buildings15010142. Disponível em: https://www.mdpi.com/2075-5309/15/1/142. Acesso em: 9 set. 2025.
Abstract: The Sustainable Development Center of the University of Brasilia is one of the modernist buildings that make up the Darcy Ribeiro campus. The architectural project contains several recommendations for the execution of a flat roof waterproofing system, as well as details for rainwater runoff and drainage, which reveals the architect’s concern with watertightness. This research seeks to identify the relationship between the pathological manifestations recognized on the roof and the details of the semicircular shape of the building, assessing the state of conservation using damage maps as an auxiliary analysis tool. This study is based on a field survey using aerophotogrammetry with a drone, the application of vector drawing software for graphic representation and discussion of the possible causes, and the agents and mechanisms of degradation at work. The results show the importance of mechanical protection for the good performance of the waterproofing system, as well as the need for correct sizing of expansion joints to absorb and relieve the stresses caused by hygrothermal variations. The incorporated methodology proved to be effective and economical in diagnosing and monitoring pathological manifestations, making it possible to plan maintenance actions that extend the useful life and preserve the intrinsic characteristics of building systems.
metadata.dc.description.unidade: Faculdade de Arquitetura e Urbanismo (FAU)
Departamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)
metadata.dc.description.ppg: Programa de Pós-Graduação em Arquitetura e Urbanismo
Licença:: This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/ licenses/by/4.0/).
DOI: https://doi.org/10.3390/buildings15010142
Appears in Collections:Artigos publicados em periódicos e afins

Show full item record " class="statisticsLink btn btn-primary" href="/handle/10482/52432/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.