http://repositorio.unb.br/handle/10482/46705
File | Description | Size | Format | |
---|---|---|---|---|
SemTexto.pdf | 1,11 kB | Adobe PDF | View/Open |
Title: | Effects of Kilohertz Effects of kilohertz frequency, burst duty cycle, and burst duration on evoked torque, perceived discomfort and muscle fatigue : a systematic review |
Authors: | Modesto, Karenina Arrais Guida Bastos, Júlia Aguillar Ivo Vaz, Marco Aurélio Durigan, João Luiz Quagliotti |
Assunto:: | Estimulação elétrica Torque Fadiga muscular |
Issue Date: | 2023 |
Publisher: | Wolters Kluwer Health |
Citation: | Effects of kilohertz frequency, burst duty cycle, and burst duration on evoked torque, perceived discomfort and muscle fatigue: a systematic review. American Journal of Physical Medicine & Rehabilitation, v. 102, n. 2, p 175-183, fev. 2023. DOI: 10.1097/PHM.0000000000001982. |
Abstract: | Kilohertz-frequency alternating current is used to minimize muscle atrophy and muscle weakness and improve muscle performance. However, no systematic reviews have evaluated the best Kilohertz-frequency alternating current parameters for this purpose. We investigated the effects of the carrier frequency, burst duty cycles, and burst durations on evoked torque, perceived discomfort, and muscle fatigue. A search of eight data sources by two independent reviewers resulted in 13 peer-reviewed studies being selected, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, and rated using the PEDro scale to evaluate the methodological quality of the studies. Most studies showed that carrier frequencies up to 1 kHz evoked higher torque, while carrier frequencies between 2.5 and 5 kHz resulted in lower perceived discomfort. In addition, most studies showed that shorter burst duty cycles (10%–50%) induced higher evoked torque and lower perceived discomfort. Methodological quality scores ranged from 5 to 8 on the PEDro scale. We conclude that Kilohertz-frequency alternating current develops greater evoked torque for carrier frequencies between 1 and 2.5 kHz and burst duty cycles less than 50%. Lower perceived discomfort was generated using Kilohertz-frequency alternating currents between 2.5 and 5 kHz and burst duty cycles less than 50%. |
metadata.dc.description.unidade: | Faculdade UnB Ceilândia (FCE) Curso de Fisioterapia (FCE-FISIO) |
DOI: | 10.1097/PHM.0000000000001982 |
Appears in Collections: | Artigos publicados em periódicos e afins |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.