Title: Avaliação do nível de ruído em marcenarias no Distrito Federal, Brasil
Evaluation of the noise level in carpentries in the Federal District, Brazil
Authors: Venturoli, Fábio
Fiedler, Nilton C.
Minetti, Luciano J.
Martins, Ildeu S.
Assunto:: Fatores ambientais
Ergonomia
Issue Date: 2003
Publisher: Departamento de Engenharia Agrícola - UFCG
Citation: Rev. bras. eng. agríc. ambient.,v.7,n.3,p.547-551,2003
Abstract: Esta pesquisa foi realizada em marcenarias no Distrito Federal, com o objetivo de se avaliar e comparar, estatisticamente, o nível de ruído emitido pelas máquinas utilizadas na fabricação de móveis em 4 empresas. A avaliação foi feita com auxílio de um decibelímetro posicionado próximo ao ouvido do trabalhador enquanto ele operava determinada máquina, conforme preceitua a NR15. Foram avaliadas 6 máquinas, serra circular, tupia, desempenadeira, desengrossadeira, furadeira horizontal e lixadeira de cinta. A análise estatística foi realizada com o uso de um modelo fatorial e teste de médias. Os resultados indicaram diferença significativa a 5% de probabilidade entre todas as máquinas, nessas empresas. O ruído médio encontrado foi de 92,16 dB(A) e o maior valor foi encontrado na serra circular na empresa 4 (101 dB(A)). A furadeira horizontal foi a única máquina, em todas as empresas, que se enquadrou dentro do limite permitido na NR15, que é de 85 dB(A) para uma jornada de trabalho de 8 horas diárias. As demais máqui-nas apresentaram problemas quanto à emissão de ruído.
This research was carried out in a carpentry in the Federal District, Brazil, with the objective to evaluate and to compare the noise level emitted by the machines used in the manufacture of furniture in four establishments. The evaluation was made with the one noise level measured and it was located as to ear of the worker while operating the machine as per NR15 norm. Six machines were evaluated. The statistical analysis was done using factorial design and mean test. The results indicated significant differences at 5% probability level among machines in the four companies. The mean noise level was of 92,16 dB(A). The highest value was found in the buzz saw in company 4 (101 dB(A)). The horizontal wimble was the only machine in all the companies that fitted with in the limits allowed in the NR15 norm (85 dB(A)) for a daily working of 8 hours. The other machines presented problems related to the noise emission.
metadata.dc.description.unidade: Em processamento
DOI: https://dx.doi.org/10.1590/S1415-43662003000300023
Appears in Collections:Artigos publicados em periódicos e afins

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/26092/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.