http://repositorio.unb.br/handle/10482/57399| Título: | Colorimetric LAMP assay for detection of Xanthomonas phaseoli pv. manihotis in Cassava through genomics : a new approach to an old problem |
| Autor(es): | Carvalho, Ian Carlos Bispo de Carvalho, Alice Maria Silva Wendland, Adriane Rossato, Maurício |
| ORCID: | https://orcid.org/0000-0002-8817-7374 https://orcid.org/0000-0002-0064-8849 |
| Afiliação do autor: | Universidade de Brasília Universidade de Brasília Embrapa Arroz e Feijão, Goiânia, Goás, Brazil Universidade de Brasília |
| Assunto: | Mandioca Diagnóstico molecular Bactérias patogênicas Amplificação isotérmica mediada por alças (LAMP) |
| Data de publicação: | Set-2024 |
| Editora: | The American Phytopathological Society (APS) |
| Referência: | CARVALHO, Ian C. Bispo et al. Colorimetric LAMP assay for detection of Xanthomonas phaseoli pv. manihotis in Cassava through genomics: a new approach to an old problem. Plant Disease, v. 108, n. 10, 2024. DOI: https://doi.org/10.1094/PDIS-08-23-1507-R. Disponível em: https://apsjournals.apsnet.org/doi/full/10.1094/PDIS-08-23-1507-RE. Acesso em: 11 nov. 2026. |
| Abstract: | Bacterial blight caused by Xanthomonas phaseoli pv. manihotis (Xpm) is considered the main bacterial disease that affects cassava, causing significant losses when not properly managed. In the present study, a fast, sensitive, and easy-to-apply method to detect Xpm via colorimetric loop-mediated isothermal amplification (LAMP) was developed. To ensure the use of a unique-to-the-target pathovar core region for primer design, 74 complete genomic sequences of Xpm together with different bacterial species and pathovars were used for comparative genomics. A total of 42 unique genes were used to design 27 LAMP primer sets, from which nine primers were synthesized, and only one (Xpm_Lp1 primer set) showed sufficient efficiency in preliminary tests. The sensitivity, assessed by a serial dilution of the type strain (IBSBF 278) DNA, yielded high sensitivity, detecting up to 100 fg. The LAMP primers showed high specificity, did not cross-react with other bacterial species or other pathovars tested, and amplified only the Xpm isolates. Tests confirmed the high efficiency of the protocol using infected or inoculated macerated cassava leaves without the need for additional sample treatment. The LAMP test developed in this study was able to detect Xpm in a fast, simple, and sensitive way, and it can be used to monitor the disease under laboratory and field conditions. |
| Unidade Acadêmica: | Instituto de Ciências Biológicas (IB) Departamento de Fitopatologia (IB FIT) |
| Programa de pós-graduação: | Programa de Pós-Graduação em Fitopatologia |
| DOI: | https://doi.org/10.1094/PDIS-08-23-1507-R |
| Versão da editora: | https://apsjournals.apsnet.org/doi/full/10.1094/PDIS-08-23-1507-RE |
| Aparece nas coleções: | Artigos publicados em periódicos e afins |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.