Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/38195
Arquivos associados a este item:
Não existem arquivos associados a este item.
Título: LC–MS bioanalytical method for simultaneous determination of latanoprost and minoxidil in the skin
Autor(es): Oliveira, Paula M.
Sampaio, Thiago R.
França, Letícia C. F.
Gratieri, Taís
Cunha-Filho, Marcílio
Gelfuso, Guilherme Martins
Assunto: Cromatografia a líquido de alta eficiência
Espectroscopia
Medicamentos
Pele
Data de publicação: 2020
Editora: Elsevier
Referência: OLIVEIRA, Paula M. et al. LC–MS bioanalytical method for simultaneous determination of latanoprost and minoxidil in the skin. Journal of Pharmaceutical and Biomedical Analysis v. 187, 113373, 2020. DOI: https://doi.org/10.1016/j.jpba.2020.113373. Disponível em: https://www.sciencedirect.com/science/article/abs/pii/S0731708520312590?via%3Dihub.
Abstract: The associationofminoxidil sulphate and latanoprostis currently emerging as a promising strategy for the treatment of androgenic alopecia, which is the most common type of scalp hair loss. In order to support the development of new pharmaceutical products containing such drugs combination, this study proposes a simple and efficient LC–MS bioanalytical method to simultaneously quantify minoxidil sulphate and latanoprostin different skin layers. Compounds separation was performed by liquid chromatography using a C18 column with gradient elution of a mobile phase composed of 0.1 % formic acid in acetonitrile and water at a flow rate of 0.5 mL min−1. Determinations were executed using mass spectrometry equipped with an ESI interface operating in a positive ionization mode. Quantification was performed using selective ion mode monitoring of m/z 210.1 for minoxidil sulphate and 433.3 for latanoprost. The matrix effect was very pronounced in samples containing some skin layers or electrolyte solution.Accordingly, a calibration curve for each contaminant group was built, leading to correlation coefficient values higher than 0.99. Additionally, lower limits of detection and quantification were obtained, and precision (repeatability and intermediate precision) achieved results with a coefficient of variation less than 15 %. Drug recovery from skin samples was higher than 70 %, fulfilling the recommendations. Also, the bioanalytical method was successfully tested in in vitro skin penetration studies proving its effectiveness in the development of topical formulations containing both drugs.
DOI: https://doi.org/10.1016/j.jpba.2020.113373
Versão da editora: https://www.sciencedirect.com/science/article/abs/pii/S0731708520312590?via%3Dihub
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro completo do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.