Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/44715
Arquivos associados a este item:
Não existem arquivos associados a este item.
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCouto, Diego-
dc.contributor.authorCunha, Rafael-
dc.contributor.authorLage, Victor-
dc.contributor.authorRocha Júnior, Valdinar de Araújo-
dc.contributor.authorSantos, Wanderson-
dc.contributor.authorFerreia Júnior, João-
dc.contributor.authorTufano, James-
dc.contributor.authorVieira, Amilton-
dc.date.accessioned2022-09-08T21:08:13Z-
dc.date.available2022-09-08T21:08:13Z-
dc.date.issued2022-
dc.identifier.citationCOUTO, Diego et al. Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force. Human Movement, v. 24, n. 2, 2023. DOI 10.5114/hm.2023.115918. Disponível em: https://doi.org/10.5114/hm.2023.115918. Acesso em: 08 set. 2022.pt_BR
dc.identifier.urihttps://repositorio.unb.br/handle/10482/44715-
dc.language.isoInglêspt_BR
dc.rightsAcesso Restritopt_BR
dc.titleValidity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull forcept_BR
dc.typeArtigopt_BR
dc.subject.keywordAptidão muscularpt_BR
dc.subject.keywordForça muscularpt_BR
dc.subject.keywordTração isométrica do meio da coxa (IMTP)pt_BR
dc.identifier.doihttps://doi.org/10.5114/hm.2023.115918pt_BR
dc.description.abstract1Purpose. The isometric mid-thigh pull (IMTP) test is a strength test usually requiring expensive equipment like a force platform. Low-cost alternatives could make IMTP testing more accessible. Previous research reported high systematic bias when comparing low-cost devices with more expensive criterion devices (force platforms). This study investigated the concurrent validity and intra-session reliability of a custom-built low-cost IMTP device using a load cell. Methods. Overall, 17 recreationally resistance-trained men (25 ± 6 years, 83 ± 14 kg, 178 ± 7 cm, 5 ± 3 years of resistance training experience) first visited the laboratory to be familiarized with testing protocols and returned 2–3 days later for IMTP testing with the low-cost device and a laboratory-grade force platform. Results. The overall bias was trivial (–0.8%, 95% CI: –5.7 to 4.3%). The typical error of the estimate was moderate (10.2%, 95% CI: 7.4–16.2%). A strong correlation of 0.91 (95% CI: 0.76–0.97) was found between peak force values from both devices; the low-cost IMTP device accounted for 81.3% of the variation in force platform. The low-cost IMTP also demonstrated acceptable scores for reliability and agreement (ICC = 0.96, 95% CI: 0.89–0.98; typical error = 5.0%, 95% CI: 3.7–7.7), similar to the criterion (ICC = 0.97, 95% CI: 0.91–0.99; typical error = 4.5%, 95% CI: 3.3–7.1). Conclusions. The low-cost IMTP device using a load cell was valid and reliable for maximal force production in recreationally trained men and provided results comparable with those of a force platform.pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-1328-069Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-1865-2790pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-6322-9804pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-6973-6006pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4378-1041pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7541-8212pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-8325-0344pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-6027-4367pt_BR
dc.description.unidadeFaculdade de Educação Física (FEF)-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.