Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/44099
Arquivos associados a este item:
Não existem arquivos associados a este item.
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFaria, S. de S.-
dc.contributor.authorSouza, P. C. de-
dc.contributor.authorJusta, C. F. da-
dc.contributor.authorRosa, S. de S. R. F.-
dc.contributor.authorRocha, Adson Ferreira da-
dc.date.accessioned2022-07-05T14:51:45Z-
dc.date.available2022-07-05T14:51:45Z-
dc.date.issued2022-
dc.identifier.citationFARIA, S. de S. et al. Analysis of the heat propagation during cardiac ablation with cooling of the esophageal wall: a bidimensional computational modeling. In: BASTOS FILHO, T. F.; Caldeira, E. M. de Oliveira; FRIZERA NETO, A. (ed.) BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, 27., 2022. IFMBE Proceedings, v. 83. Springer, Cham. DOI: https://doi.org/10.1007/978-3-030-70601-2_16.pt_BR
dc.identifier.urihttps://repositorio.unb.br/handle/10482/44099-
dc.language.isoInglêspt_BR
dc.publisherSpringerpt_BR
dc.rightsAcesso Restritopt_BR
dc.titleAnalysis of the heat propagation during cardiac ablation with cooling of the esophageal wall : a bidimensional computational modelingpt_BR
dc.typeTrabalhopt_BR
dc.subject.keywordAblação cardíacapt_BR
dc.subject.keywordAblação de cateterespt_BR
dc.subject.keywordModelação por computadorpt_BR
dc.subject.keywordLesão térmicapt_BR
dc.subject.keywordArrefecimento esofágicopt_BR
dc.identifier.doihttps://doi.org/10.1007/978-3-030-70601-2_161pt_BR
dc.description.abstract1Atrial fibrillation (AF) is a cardiac arrhythmia that affects around 33 million people worldwide. A standard form of treatment for AF is cardiac ablation with the radiofrequency catheter (RFCA). RFCA generates heat through the ablation electrode, and this process can cause severe lesions in the atrial and esophageal tissues. This work presents a two-dimensional computational model that uses geometry and boundary conditions that approximate cardiac ablation conditions with a non-irrigated catheter. The paper’s objective is to simulate the RFCA and analyze the heat propagation during cardiac ablation when the esophageal wall is cooled down. The esophagus, the connective tissue, and the heart wall were simulated, assuming laminar blood flow in the heart wall. The simulated electrode temperatures were 60, 70, and 80 °C for 60 seconds with constant peak voltage. The cooling temperature was 0 °C. The results showed that cooling decreases the temperature between tissues. The temperature in connective-cardiac tissue dropped by approximately 6.51%. In the esophageal-connective tissue, the temperature decreased by about 28.22%. In all cases, there was also a slowing in temperature increase, which can help prevent tissue damage. The results suggest that the method has significant potential for improving the safety of RFCA.pt_BR
dc.description.unidadeFaculdade de Tecnologia (FT)-
dc.description.unidadeDepartamento de Engenharia Elétrica (FT ENE)-
Aparece nas coleções:Trabalhos apresentados em evento

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.