Campo DCValorIdioma
dc.contributor.authorBoeckmann, Lara Mabelle Milfontpt_BR
dc.contributor.authorRodrigues, Maria Cristina Soarespt_BR
dc.date.accessioned2019-01-02T13:52:24Z-
dc.date.available2019-01-02T13:52:24Z-
dc.date.issued2018pt_BR
dc.identifier.citationBOECKMANN, Lara Mabelle Milfont; RODRIGUES, Maria Cristina Soares. Adaptação e validação de checklist de segurança cirúrgica na cesárea. Texto & Contexto - Enfermagem, Florianópolis, v. 27, n. 3, e2780017, 2018. DOI: http://dx.doi.org/10.1590/0104-070720180002780017. Disponível em: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-07072018000300326&lng=en&nrm=iso. Acesso em: 30 jan. 2019. Epub Aug 27, 2018.pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/33477-
dc.description.abstractObjetivo: adaptar e validar um instrumento de segurança cirúrgica na cesárea, com base em revisão integrativa da literatura, e no protocolo e checklist de segurança cirúrgica da Organização Mundial da Saúde. Método: estudo metodológico, com triangulação de dados, envolvendo um total de 43 participantes, sendo oito juízes para a validação de conteúdo e aparente do instrumento, utilizando-se a técnica Delphi, e para a validação semântica outros 35 profissionais da equipe cirúrgica de um hospital público do Distrito Federal, Brasil. Foi aplicado o coeficiente de confiabilidade ao instrumento. Resultados: o instrumento alcançou índice de validade de conteúdo geral de 0,9 e concordância interavaliadores de 1. O coeficiente total do alfa de Cronbach foi de 0,86, e a média dos escores das dimensões obteve notas elevadas. Conclusão: o instrumento apresentou validade nos três critérios estudados e confiabilidade para ser aplicado em futuros estudos que avaliem a segurança cirúrgica na cesárea.pt_BR
dc.language.isoptpt_BR
dc.publisherUniversidade Federal de Santa Catarina, Programa de Pós Graduação em Enfermagempt_BR
dc.rightsAcesso Abertopt_BR
dc.titleAdaptação e validação de checklist de segurança cirúrgica na cesáreapt_BR
dc.titleAdaptación y validación del checklist de seguridad cirúrjica en la cesáreapt_BR
dc.titleAdaptation and validation of a surgical safety checklist in the cesarean deliverypt_BR
dc.typeArtigopt_BR
dc.subject.keywordMulheres - saúde e higienept_BR
dc.subject.keywordSegurança do pacientept_BR
dc.subject.keywordLista de verificaçãopt_BR
dc.subject.keywordEnfermagempt_BR
dc.subject.keywordCesarianapt_BR
dc.rights.licenseThis is an Open Access article distributed under the terms of the Creative Commons (CC BY).-
dc.identifier.doihttp://dx.doi.org/10.1590/0104-070720180002780017pt_BR
dc.description.abstract1Objective: adapt and validate a surgical safety instrument in the cesarean delivery, based on an integrative review of the literature, and on the World Health Organization protocol and surgical safety checklist. Method: methodological study, with triangulation of data, involving a total of 43 participants, being eight judges for the validation of content and apparent of the instrument, using the Delphi technique, and for the semantic validation, another 35 professionals from the surgical team of a public hospital in the Federal District, Brazil. The reliability coefficient was applied to the instrument. Results: the instrument achieved general content validity index of 0.9 and inter-rater agreement of 1. The total coefficient of Cronbach’s alpha was 0.86, and the mean score of the dimensions obtained high scores. Conclusion: the instrument presented validity in the three criteria studied and reliability to be applied in future studies evaluating the surgical safety in cesarean deliveries.-
dc.description.abstract2Objetivo: adaptar y validar un instrumento de seguridad quirúrgica en la cesárea, con base en la revisión integrativa de la literatura y en el protocolo y checklist de seguridad quirúrgica de la Organización Mundial de la Salud. Método: estudio metodológico con triangulación de datos envolviendo un total de 43 participantes, siendo ocho jueces para la validación del contenido aparente del instrumento. Se utilizó la técnica Delphi y para la validación semántica se usaron otros 35 profesionales del equipo quirúrgico de un hospital público del Distrito Federal, Brasil. Se aplicó el coeficiente de confiabilidad en el instrumento. Resultados: el instrumento alcanzó el índice de validad del contenido general de 0,9 y la concordancia de los interevaluadores fue de 1. El coeficiente total del alfa de Cronbach fue de 0,86 y el promedio de los resultados de las dimensiones obtuvo notas elevadas. Conclusión: el instrumento presentó validad en los tres criterios estudiados y confiabilidad para ser aplicado en futuros estudios que evalúen la seguridad quirúrgica en la cesárea.-