Título: | Skin model and some processing properties of a drilling simulation in the abdominal |
Autor(es): | Colón, Diego Rosa, Suélia de Siqueira Rodrigues Fleury Oliveira, Danilo S. Balthazar, José M. Reis, Célia Aparecida dos |
Assunto: | Perfuração abdominal Bond Graph Modelagem |
Data de publicação: | Set-2015 |
Editora: | International Journal of Advanced Engineering Research and Science (IJAERS) |
Referência: | COLÓN, Diego et al. Skin model and some processing properties of a drilling simulation in the abdominal. International Journal of Advanced Engineering Research and Science (IJAERS), Jaipur, v. 2, n. 9, p. 50-55, set. 2015. Disponível em: <http://ijaers.com/issue_sept_2015.php>. Acesso em: 7 maio 2018. |
Abstract: | We know that the skin is a complex organ, and there is a need to measure the complex mechanical properties of the human skin by means of a mathematical representation capable of simulating the deformations that occur during the movements of the body and surgical procedures. We propose for this modeling an analogy between: a) resistance represented by the shock absorber, in this study the modeling will be based on the compression cycle, which occurs once the needle is inserted in the skin, compressing it; b) elasticity given by a spring with a rigidity k; and c) mass, which in turn constitutes the systems inertia resistance to displacement. With the proposed analysis of skin perforation we aim to obtain a model by relating the force applied by the needle to its velocity in the hypodermis. The results shows the steps outlined to convert the analogous system of human skin into a liaison graph, Bond Graph. As discussed by the authors, all data concerning skin are embedded in uncertainty, due especially to the following factors: spatial distribution of the organ, build and dimensions of the individual and lack of specific literature. The skin was thus modeled through a methodology based on the comparison between the real system and a model of the real system. This paper shows the mechanical model that represents skin and the injection in a procedure of abdominal perforation. |
Unidade Acadêmica: | Faculdade UnB Gama (FGA) |
Licença: | International Journal of Advanced Engineering Research and Science (IJAERS) - This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License (CC BY SA 4.0). Fonte: http://ijaers.com/issue_sept_2015.php. Acesso em: 7 maio 2018. |
Aparece nas coleções: | Artigos publicados em periódicos e afins |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.