Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/28878
Arquivos associados a este item:
Arquivo TamanhoFormato 
ARTIGO_IncertidumbreMedicionMasa.pdf1,18 MBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorValdés Arencibia, Rosendapt_BR
dc.contributor.authorPiratelli Filho, Antoniopt_BR
dc.contributor.authorCrespo, Amado Cruzpt_BR
dc.contributor.authorDíaz Cedré, Eduardopt_BR
dc.date.accessioned2017-12-07T05:03:03Z-
dc.date.available2017-12-07T05:03:03Z-
dc.date.issued2013-06pt_BR
dc.identifier.citationVALDÉS ARENCIBIA, Rosenda et al. Incertidumbre de la medición de masa en la determinación de los parámetros de consumo de electrodos de recargue. Soldagem & Inspeção, São Paulo, v. 18, n. 2, p. 110-117, abr./jun. 2013. DOI: https://doi.org/10.1590/S0104-92242013000200004. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-92242013000200004&lng=es&tlng=es. Acesso em: 20 ago. 2020.pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/28878-
dc.language.isoespt_BR
dc.publisherAssociação Brasileira de Soldagempt_BR
dc.rightsAcesso Abertopt_BR
dc.titleIncertidumbre de la medición de masa en la determinación de los parámetros de consumo de electrodos de recarguept_BR
dc.title.alternativeMeasurement uncertainty of mass in the determination of the consumption parameters of hardfacing electrodes-
dc.typeArtigopt_BR
dc.subject.keywordSoldagempt_BR
dc.subject.keywordRastreabilidadept_BR
dc.subject.keywordMassa (Física)pt_BR
dc.rights.licenseSoldagem & Inspeção - (CC BY-NC) - Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons. Fonte: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-92242013000200004&lng=es&tlng=es. Acesso em: 20 ago. 2020.-
dc.identifier.doihttps://dx.doi.org/10.1590/S0104-92242013000200004pt_BR
dc.description.abstract1This work presents the evaluation of the uncertainty of the measurements to determine the consumption parameters of hardfacing electrode, emphasizing the mass measurement. The experimentation was carried out obtaining deposits at three levels of current (120 A, 145 A y 160 A) and measuring the time spent in welding, the length of the welds the test plate and electrode mass (initial and final). Based on these results, the consumption parameters were also determined. The uncertainty related to the measurements the mass of the samples, the mass consumption of the electrode, the deposited mass and consumption parameters was determined. The results showed that the deposition efficiency increase as a function of the current, turning the best result (74.12 %) at 120 A. The expanded measurement uncertainty associated to consumption parameters changed between 1.47% and 2.41% for the deposition efficiency, 0.4 g/min and 0.6 g/min for the consumption rate vary of 0.6 g/min to 0.7 g/min for the deposition rate.-
dc.description.abstract2Este trabajo presenta la evaluación de la incertidumbre de las mediciones realizadas para la determinación de los parámetros de consumo de electrodos de recargue, dando énfasis a la medición de masa. Para ello fueron realizados tres depósitos a tres niveles de corriente (120 A, 145 A y 160 A, respectivamente), registrándose el tiempo de soldadura, la longitud del cordón, así como la masa inicial y final de las probetas y de los electrodos. A partir de los datos anteriores fueron determinados los parámetros de consumo. Fue calculada la incertidumbre asociada a la masa de las probetas, a la masa consumida del electrodo, a la masa depositada y a los parámetros de consumo. Al finalizar el trabajo se comprobó que el rendimiento del depósito muestra un comportamiento decreciente con la corriente, siendo el mejor resultado de (74,12) % para una corriente de soldadura de 120 A. Los valores de incertidumbre expandida para el rendimiento varían entre 1,47 % y 2,41 %, para la tasa de consumo fueron obtenidos valores entre 0,4 g/min y 0,6 g/min, mientras que para la tasa de deposición la incertidumbre varía de 0,6 g/min a 0,7 g/min.-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.