Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/28231
Arquivos associados a este item:
Arquivo TamanhoFormato 
01.pdf445,25 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorRadaelli, Regispt_BR
dc.contributor.authorWilhelm Neto, Eurico Nestorpt_BR
dc.contributor.authorMarques, Martim Francisco Bottaropt_BR
dc.contributor.authorPinto, Ronei Silveirapt_BR
dc.date.accessioned2017-12-07T04:57:31Z-
dc.date.available2017-12-07T04:57:31Z-
dc.date.issued2011pt_BR
dc.identifier.citationRev. bras. cineantropom. desempenho hum. (Online),v.13,n.2,p.87-93,2011pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/28231-
dc.description.abstractOs objetivos do presente estudo foram: a) observar se há diferença entre os valores de espessura muscular (EM) medidos por ultrassonografia e qualidade muscular (QM) de três diferentes pontos nos músculos flexores de cotovelo e extensores de joelho, b) analisar a correlação das medidas de EM e força isométrica de flexão de cotovelo e extensão de joelho. Sessenta e nove sujeitos homens, fisicamente ativos, participaram do estudo. Os valores de produção de força isométrica de flexão de cotovelo e extensão de joelho foram obtidos nos ângulos de 90° e 60°, respectivamente. A medida de EM foi realizada em três pontos nos flexores de cotovelo (proximal - BB1, médio - BB2, e distal - BB3) e extensores de joelho (proximal - RI1, medial - RI2, e distal - RI3). As diferenças entre as três medidas de EM e QM foram avaliadas por meio da one-way ANOVA para medidas repetidas, e a correlação entre EM e produção de força foi testada utilizando correlação de Pearson. O nível de significância utilizado foi de p<0,05. A EM e a QM diferiram estatisticamente nos três pontos de medidas, tanto nos flexores do cotovelo quanto nos extensores do joelho (p<0,001). As correlações entre as medidas de EM dos flexores de cotovelo nos pontos BB1, BB2 e BB3 e a produção de força isométrica foram r=0,57, r=0,52 e r=0,59 (p<0,05), respectivamente. Já nos extensores de joelho, estas foram de r=0,47, r=0,51 e r=0,53 (p<0,01), nos pontos RI1, RI2, e RI3, respectivamente. Os resultados do presente estudo demonstraram que o ponto de medida exerce influência significativa na EM e QM. Os valores de EM relacionam-se com os de produção de força isométrica dos flexores de cotovelo e extensores de joelho.pt_BR
dc.description.abstractThe aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal - BB1, middle - BB2, and distal - BB3) and knee extensors (proximal - RI1, middle - RI2, and distal - RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson's correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01). There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors (p<0.001The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.pt_BR
dc.language.isoporpt_BR
dc.publisherUniversidade Federal de Santa Catarinapt_BR
dc.rightsAcesso Abertopt_BR
dc.titleEspessura e qualidade musculares medidas a partir de ultrassonografia: influência de diferentes locais de mensuraçãopt_BR
dc.titleMuscle thickness and muscle quality measured by ultrasound: influence of different sites of measurementpt_BR
dc.typeArtigopt_BR
dc.subject.keywordUltrasonografiapt_BR
dc.subject.keywordEspessura muscularpt_BR
dc.subject.keywordQualidade muscularpt_BR
dc.subject.keywordForça muscularpt_BR
dc.identifier.doihttps://dx.doi.org/10.5007/1980-0037.2011v13n2p87pt_BR
dc.description.unidadeEm processamento-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.