http://repositorio.unb.br/handle/10482/24469
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2017_DeniseCardosoGuimaraes.pdf | 5,4 MB | Adobe PDF | Visualizar/Abrir |
Título: | Correlação numérico- experimental entre o método dos elementos de contorno e termografia aplicados a placas de argamassa |
Autor(es): | Guimarães, Denise Cardoso |
Orientador(es): | Gomes, Gilberto |
Coorientador(es): | Bauer, Elton |
Assunto: | Fachadas de edificações Termografia infravermelha Fluxo de calor Revestimentos - argamassa - Engenharia civil Argamassa - resistência de materiais Edificações |
Data de publicação: | 11-Set-2017 |
Data de defesa: | 2-Jun-2017 |
Referência: | GUIMARÃES, Denise Cardoso. Correlação numérico- experimental entre o método dos elementos de contorno e termografia aplicados a placas de argamassa. 2017. xviii, 86 f., il. Dissertação (Mestrado em Estruturas e Construção Civil)—Universidade de Brasília, Brasília, 2017. |
Resumo: | As fachadas são elementos que desempenham um papel muito importante nas edificações, pois são responsáveis por garantir e controlar com eficácia as trocas de calor, ar e luminosidade existentes entre o interior e exterior da edificação, além da qualidade visual (estética da edificação). Sabe-se que, ao longo do tempo, os revestimentos das fachadas estão expostos as intempéries, as quais podem gerar danos ou anomalias em sua estrutura, como descolamento de cerâmicas.Por outro lado, a busca por resultados com menor custo, o uso de processos não-destrutivos, bem como o uso de procedimentos e ferramentas numéricas que permitam análises rápidas, como o Método dos Elementos de Contorno (MEC), têm se tornado importantes tópicos neste campo de pesquisa. Neste contexto, o presente trabalho tem como objetivo estudar a influência da profundidade das fissuras presentes nos revestimentos de fachada, através da modelagem do fluxo de calor de uma placa de argamassa contendo duas fissuras, submetida a um ciclo de aquecimento direto. Para tanto se realizou uma modelagem numérica, onde a interface gráfica chamada BEMLAB2D foi responsável pela geração da malha (frontal e lateral) em elementos de funcionalidade constante, e um programa de análises, escrito em MATLAB, para problemas de Potencial via MEC com Sub-região, responsável pelos cálculos de temperatura e fluxo em pontos do contorno e interior. Observando os resultados obtidos através da modelação numérica e comparando com os resultados experimentais, constata-se que é possível detectar diferenças no comportamento do fluxo de calor devido à profundidade das fissuras, o que demonstra também a acurácia e eficiência da análise junto aos dados experimentais. |
Abstract: | The facades are elements that perform an important role in the buildings, either for ensuring and effectively control the heat, air and light changes between the interior and exterior of the building, as well as the visual quality (building aesthetics). Over time, the outer coating is exposed to the weather, which can cause damage or structural anomalies as detachment of ceramics, for example. On the other hand, the search for results at lower cost, the use of non-destructive processes, and the use of procedures and numerical tools which enable quick and efficient analyzes, such as the Boundary Element Method (BEM), have become an important topics in scientific research. In this context, the present work aims to study the influence of cracks depth on facade coatings by modeling the heat flow of a mortar plate containing two cracks, subjected to a direct heating cycle. Here, the methodology consists of a numerical modeling, based on data from thermography extracted from experimental tests on cracked mortar plates, where two programs has been used: the BEMLAB2D GUI for modeling and boundary element mesh generation, as well as an analysis program, written in MATLAB, for Potential problems via BEM with Sub-region, for calculations of temperature and flow at boundary and internal points. Observing the results of numerical modeling and comparing the experimental results, it is found that it is possible to detect differences in the heat flow behavior due to the cracks depth, which also demonstrates the accuracy and efficiency of the methodology adopted between numerical and experimental analysis. |
Unidade Acadêmica: | Faculdade de Tecnologia (FT) Departamento de Engenharia Civil e Ambiental (FT ENC) |
Informações adicionais: | Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. |
Programa de pós-graduação: | Programa de Pós-Graduação em Estruturas e Construção Civil |
Licença: | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. |
DOI: | http://dx.doi.org/10.26512/2017.06.D.24469 |
Aparece nas coleções: | Teses, dissertações e produtos pós-doutorado |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.