Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/16038
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_SistemaAcumulacionEnergia.pdf450,24 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorRodrigues, E. M. C.-
dc.contributor.authorCamargo, Ivan Marques de Toledo-
dc.contributor.authorOliveira, Marco Aurélio Gonçalves de-
dc.date.accessioned2014-08-06T15:44:45Z-
dc.date.available2014-08-06T15:44:45Z-
dc.date.issued1998-
dc.identifier.citationRODRIGUES, M. E. C.; CAMARGO, I. M. T.; OLIVEIRA, M. A. G. de. Sistema de acumulacion de energia para alimentacion de la iluminacion publica durante las horas de punta. Separata de: Información Tecnológica, La Serena, v. 9, n. 3, p. 309-314, 1998.en
dc.identifier.urihttp://repositorio.unb.br/handle/10482/16038-
dc.description.abstractRESUMENen
dc.description.abstractEn este artículo se presenta un análisis técnico y económico de una alternativa de solución para el problema causado en la distribución de energía eléctrica al sistema público de alumbrado durante las horas de máxima demanda. La alternativa propuesta considera el uso de un conjunto rectificador-baterla-invertidor, el cual es automáticamente recargado durante el período de baja demanda. Se realizaron simulaciones por computador para estudiar la factibilidad de impiementación del sistema propuesto. Estimaciones de costo indican que el costo de operación del sistema por 30 minutos de operación es del orden de US$ 2000/kW, mientras que la inversión necesaria para este sistema es del orden de US$ 4000/kW. Esto demuestra que la solución propuesta es técnica y económicamente factible. _________________________________________________________________________________ ABSTRACTen
dc.description.abstractThis article shows a technical and economic analysis of a solution for the problem produced in the distribution of electrical energy to the public illuminating system during the peak demand period. The proposed alternative considers the use of a rectifier-battery-inverter set, which is automatically recharged during the period of low demand. Computer simulations were carried out to study the feasibility of the proposed system. Cost estimations indicate that the cost of operating the system for 30 minutes is of the order of US$ 2000/kW, while the necessary investment for this system is of the order of US$ 4000/kW. This shows that the proposed solution is both technical and economically feasible.en
dc.language.isoPortuguêsen
dc.publisherCentro de Información Tecnológicaen
dc.rightsAcesso Abertoen
dc.titleSistema de acumulacion de energia para alimentacion de la iluminacion publica durante las horas de puntaen
dc.title.alternativeEnergy storage system to supply the public illuminating system during the peak demanden
dc.typeArtigoen
dc.subject.keywordEnergia elétricaen
dc.subject.keywordEnergia elétrica - fornecimentoen
dc.subject.keywordEnergia elétrica - armanezamentoen
dc.subject.keywordEnergia elétrica - distribuiçãoen
dc.rights.licenseInformación tecnológica - Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons.en
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.