Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/54911
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
EVENTO_CalorExtremoAmbientes.pdf1,53 MBAdobe PDFVisualizar/Abrir
Título: Calor extremo em ambientes de saúde : conforto térmico da Unidade Básica de Saúde 1 - Paranoá - Distrito Federal
Outros títulos: Calor extremo en entornos de atención médica : confort térmico de la Unidad Básica de Salud 1 – Paranoá - Distrito Federal
Extreme heat in healthcare environments : thermal comfort of Basic Health Unit 1 - Paranoá- Distrito Federal
Autor(es): Oliveira, Rejane Martins Viegas de
Araújo, Ana Victória de
Araújo, Isadora Costa de
Silva, Caio Frederico e
ORCID: https://orcid.org/0000-0002-1444-0125
https://orcid.org/0000-0001-8910-1841
https://orcid.org/0000-0003-1101-569X
Afiliação do autor: Universidade de Brasília
Universidade de Brasília
Universidade de Brasília
Universidade de Brasília
Assunto: Unidade Básica de Saúde
Conforto térmico
Data de publicação: 2025
Editora: ANTAC
Referência: VIEGAS, Rejane Martins; ARAÚJO, Ana Victória de, ARAÚJO, Isadora Costa de; SILVA, Caio Frederico e; CASTRO, Thiago Figueiredo de. Calor extremo em ambientes de saúde: conforto térmico da Unidade Básica de Saúde 1 - Paranoá - Distrito Federal. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 18., 2025. Anais [...]. [S. l.]: ANTAC, 2025. DOI: https://doi.org/10.46421/encacelacac.v18i1.7197. Disponível em: https://eventos.antac.org.br/index.php/encac/article/view/7197. Acesso em: 18 jun. 2026.
Resumo: Este artigo apresenta o monitoramento da condição térmica da Unidade Básica de Saúde 1, localizada no Paranoá, Distrito Federal. A metodologia aplicada reuniu a caracterização do objeto de estudo, medição in loco das variáveis microclimáticas, comparação com os dados registrados pelo INMET na Estação Automática do Paranoá e a verificação da condição térmica do ambiente mediante a ferramenta CBE Thermal Comfort Tool. As medições, intervaladas em 5 minutos, foram realizadas em um consultório padrão da UBS, durante uma semana de primavera. Os resultados indicaram que o ambiente permaneceu fora da faixa de conforto nos dias analisados, além da temperatura do ar superar, na maior parte do tempo, os valores medidos pelo INMET, o que comprova que o consultório é termicamente inadequado. Este trabalho é, portanto, uma iniciativa que, pode contribuir para outros estudos de UBS inseridas em circunstâncias climáticas semelhantes à de Brasília.
Abstract: This article presents the monitoring of the thermal conditions of the Basic Health Unit 1, located in Paranoá, Federal District. The methodology applied included the characterization of the object of study, on-site measurement of microclimatic variables, comparison with data recorded by INMET at the Paranoá Automatic Station, and verification of the thermal conditions of the environment using the CBE Thermal Comfort Tool. The measurements, at 5-minute intervals, were performed in a standard UBS office during a week in spring. The results indicated that the environment remained outside the comfort range on the days analyzed, in addition to the air temperature exceeding, most of the time, the values measured by INMET, which proves that the office is thermally inadequate. This work is, therefore, an initiative that can contribute to other studies of UBS inserted in climatic conditions similar to those of Brasília.
Resumen: Este artículo presenta el monitoreo de las condiciones térmicas de la Unidad Básica de Salud 1, ubicada en Paranoá, Distrito Federal. La metodología aplicada incluyó la caracterización del objeto de estudio, la medición in situ de variables microclimáticas, la comparación con los datos registrados por el INMET en la Estación Automatizada de Paranoá y la verificación de las condiciones térmicas del ambiente mediante la Herramienta de Confort Térmico CBE. Las mediciones, a intervalos de 5 minutos, se realizaron en una oficina estándar de UBS durante una semana de primavera. Los resultados indicaron que el ambiente se mantuvo fuera del rango de confort en los días analizados, además de que la temperatura del aire superó, en la mayoría de los casos, los valores medidos por el INMET, lo que demuestra que la oficina es térmicamente inadecuada. Este trabajo es, por lo tanto, una iniciativa que puede contribuir a otros estudios de UBS insertadas en condiciones climáticas similares a las de Brasilia.
Unidade Acadêmica: Faculdade de Arquitetura e Urbanismo (FAU)
Faculdade de Medicina (FM)
Licença: Copyright (c) 2025 ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO Creative Commons License Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License. Fonte: https://eventos.antac.org.br/index.php/encac/article/view/7197. Acesso em: 18/06/2026.
DOI: https://doi.org/10.46421/encacelacac.v18i1.7197
Aparece nas coleções:Trabalhos apresentados em evento

Mostrar registro completo do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.