Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/46358
Files in This Item:
File Description SizeFormat 
EVENTO_SeismicSafetyAssessme.pdf8,52 MBAdobe PDFView/Open
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRodrigues, Philipe Queiroz-
dc.contributor.authorPantoja, João da Costa-
dc.contributor.authorMiranda, Paulo de Souza Tavares-
dc.date.accessioned2023-08-21T15:05:55Z-
dc.date.available2023-08-21T15:05:55Z-
dc.date.issued2023-
dc.identifier.citationRODRIGUES, P. Q.; PANTOJA, J. C.; MIRANDA, P. S. T. Seismic safety assessment of “Palácio do Itamaraty” at Brasília reliability-based. In: INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE CIVIL ENGINEERING (IALCCE 2023), 8., 2023, Milan, Italy. Proceedings [...]. London, UK: CRC Press, Taylor & Francis Group, 2023. p. 1885-1892. Disponível em: https://www.taylorfrancis.com/books/oa-edit/10.1201/9781003323020/life-cycle-structures-infrastructure-systems-fabio-biondini-dan-frangopol.pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/46358-
dc.description.abstractIn Brasilia (Brazil) heritage buildings have been designed without considering seismic loads. The aim of the paper is to assess seismic behavior of reinforced concrete structure of “Palácio do Itamaraty”. In this study, Monte Carlo simulation technique is implemented in Hirosawa method to examine structural level of safety. Reliability indexes for each floor are estimated and comparisons to target reliability indexes are made. The sensitivity of different input variables is also studied. Seismic indexes of structure for each floor remained greater than seismic demand indexes in all Brazilian seismic zones through Hirosawa method. Despite of, inadequate reliability indexes is noticed in all floor, which implies that structure is not enough to guarantee an adequate performance. Sensitivity analysis shows the influence of irregularity of structure in seismic response. The results highlight the importance of a probabilistic approach by Hirosawa Method to assertive decisions of conservation and rehabilitation of architectural heritage subject to seismic hazards.pt_BR
dc.language.isoengpt_BR
dc.publisherTaylor & Francispt_BR
dc.rightsAcesso Abertopt_BR
dc.titleSeismic safety assessment of “Palácio do Itamaraty” at Brasília reliability-basedpt_BR
dc.typeTrabalho apresentado em eventopt_BR
dc.subject.keywordConcreto armadopt_BR
dc.subject.keywordMétodo de Hirosawapt_BR
dc.subject.keywordPalácio do Itamaratypt_BR
dc.rights.license© 2023 The Author(s), ISBN 978-1-003-32302-0 Open Access: www.taylorfrancis.com, CC BY-NC-ND 4.0 license.pt_BR
dc.identifier.doi10.1201/9781003323020pt_BR
dc.contributor.affiliationUniversidade de Brasíliapt_BR
dc.contributor.affiliationUniversidade de Brasíliapt_BR
dc.contributor.affiliationInstituto Federal de Educação, Ciência e Tecnologia do Cearápt_BR
dc.description.unidadeFaculdade de Arquitetura e Urbanismo (FAU)pt_BR
dc.description.unidadeDepartamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)pt_BR
dc.description.ppgPrograma de Pós-Graduação em Arquitetura e Urbanismopt_BR