Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/26063
Files in This Item:
File SizeFormat 
17133.pdf204,92 kBAdobe PDFView/Open
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSelmi, André Luispt_BR
dc.contributor.authorLins, Bruno Testonipt_BR
dc.contributor.authorBarbudo-Selmi, Glenda Ramalhopt_BR
dc.contributor.authorMendes, Guiherme Maiapt_BR
dc.date.accessioned2017-12-07T04:38:30Z-
dc.date.available2017-12-07T04:38:30Z-
dc.date.issued2003pt_BR
dc.identifier.citationCienc. Rural,v.33,n.5,p.875-880,2003pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/26063-
dc.description.abstractEste estudo comparou o efeito na biomecânica articular de dois fios de sutura, aço e polipropileno, na estabilização do joelho após transecção do ligamento cruzado cranial de cães, utilizando-se a técnica extra-articular de sutura fabelo-tibial. O centro instantâneo de movimento e o vetor velocidade resultante, foram calculados por meio de análise radiográfica das articulações fêmur-tíbio-patelares de doze cães, antes e após a desestabilização e estabilização articular. Todas as articulações apresentavam centro instantâneo e vetor velocidade normais antes da transecção do ligamento. Após a mesma, observou-se o posicionamento anormal do vetor velocidade em onze articulações. Na análise radiográfica posterior à estabilização articular, quatro articulações do grupo nos quais foi empregado o fio de aço continuaram apresentando posicionamento anormal do vetor velocidade, enquanto todas as articulações do grupo em que foi utilizado o fio de polipropileno apresentaram vetor velocidade em posição tangente às superfícies ósseas. Conclui-se que o fio de polipropileno é mais indicado na estabilização extra-articular por manter a biomecânica articular inalterada.pt_BR
dc.description.abstractThis study evaluated the effect of two suture materials, stainless steel wire and polypropylene, on the stifle joint biomechanics by means of analysis of the instantaneous center of motion after stabilization of cranial cruciate ligament-deficient stifle with the fabelo-tibial suture technique. The instantaneous center of motion and resulting velocity vectors were determined by radiographic examination of the stifle joint in twelve dogs before and after cranial cruciate ligament transection, and after joint stabilization. All the stifles showed normally positioned instantaneous centers of motion and velocity vectors before cranial cruciate ligament transection. Eleven joints had abnormally positioned velocity vectors after transection of the cranial cruciate ligament. After joint stabilization, four joints in the stainless steel wire suture group continued showing abnormal velocity vectors, while all stifles joints in the polypropylene group had normal positioned velocity vectors. The polypropylene suture is more adequate for extra-articular stabilization as it maintains the normal joint biomechanics.pt_BR
dc.language.isoporpt_BR
dc.publisherUniversidade Federal de Santa Mariapt_BR
dc.rightsAcesso Abertopt_BR
dc.titleCentro instantâneo de movimento, na avaliação ex-vivo da reconstrução extra-articular fabelo-tibial, após transecção do ligamento cruzado cranial em cãespt_BR
dc.titleInstantaneous center of motion following ex-vivo extra-articular stabilization for the cranial cruciate ligament-deficient stiflept_BR
dc.typeArtigopt_BR
dc.subject.keywordCirurgiapt_BR
dc.subject.keywordBiomecânicapt_BR
dc.subject.keywordOrtopediapt_BR
dc.identifier.doihttps://dx.doi.org/10.1590/S0103-84782003000500013pt_BR
dc.description.unidadeEm processamento-
Appears in Collections:Artigos publicados em periódicos e afins

Show simple item record " class="statisticsLink btn btn-primary" href="/handle/10482/26063/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.