http://repositorio.unb.br/handle/10482/18905| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| 2015_ElaineJaricunaPereiraDeAlbuquerque.pdf | 12,52 MB | Adobe PDF | Visualizar/Abrir |
| Título: | Punção em lajes lisas com armadura de cisalhamento e pilar de canto reentrante |
| Outros títulos: | Punching of flat slab with shear reinforcement and reentrant corner column |
| Autor(es): | Albuquerque, Elaine Jaricuna Pereira de |
| Orientador(es): | Melo, Guilherme Sales Soares de Azevedo |
| Assunto: | Lajes - concreto Concreto armado Lajes lisas |
| Data de publicação: | 11-Dez-2015 |
| Data de defesa: | 7-Ago-2015 |
| Referência: | ALBUQUERQUE, Elaine Jaricuna Pereira de. Punção em lajes lisas com armadura de cisalhamento e pilar de canto reentrante. 2015. xxxix, 340 f., il. Tese (Doutorado em Estruturas e Construção Civil)—Universidade de Brasília, Brasília, 2015. |
| Abstract: | In failure slab-column connection failure of flat slabs is observed high stresses are originated by that of bending and shearing efforts, which can cause failure by punching with a load lower than the bending. The types of slab-column connection, internal, edge, corner and re-entrant corner can appear in any deck. However the connection slab-column of reentrant corner is not discussed by any research as the other cases, its mechanical model and its behavior with unbalanced moments in one or both directions are unknown. In this research were analyzed experimentally 12 flat slabs with thickness of 180 mm, supported by a square column with sides of 300 mm and molded with machined concrete with average strength of 45 MPa. The experimental results were: strain in bending, shear and torsion reinforcement; concrete strains; vertical displacement; map of cracking; ultimate loads; rotations of the slabs and failure modes. The variables were: eccentricity, bending reinforcement ratio, amount of shear reinforcement and torsion reinforcement. Strength of punching shear get in the tests was compared with the strength provided by the NBR 6118 code (2014), Eurocode 2 (2004), ACI 318 (2014) and MC2010 (2013), but all the standards had to be adapted because they do not cover punching in slabs with reentrant corner column. Also a numerical simulation was made using the ATENA software designed to make non-linear three-dimensional analysis of reinforced concrete structures. Thus, the data monitored in the laboratory ware correlated with the results from finite element modeling. Some of the major contributions of this study were to show the general behavior of the slab connection with reentrant corner column with respect to displacements, strains, cracking, failure mode and failure surface; analyze the behavior and the adapted codes; and show how to treat this type of connection. |
| Unidade Acadêmica: | Faculdade de Tecnologia (FT) Departamento de Engenharia Civil e Ambiental (FT ENC) |
| Informações adicionais: | Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. |
| Programa de pós-graduação: | Programa de Pós-Graduação em Estruturas e Construção Civil |
| Licença: | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. |
| DOI: | http://dx.doi.org/10.26512/2015.08.T.18905 |
| Aparece nas coleções: | Teses, dissertações e produtos pós-doutorado |